| Figure 5 |
![]() |
| When the capacitor value is set at the extremes of its required range, 50 and 200 µF, the linear PID controller (lower plot) exhibits substantial under- and overshoot, respectively. For the same range of values, the fuzzy controller (upper plot) exhibits far less variation in overshoot. |
back |