Precisely measure settling time to 1 ppm

Intense, extensive, and protracted effort yields a measurement circuit with 20-bit resolution.

By Jim Williams, Linear Technology -- EDN, March 4, 2010

AT A GLANCE
Measuring anything to 1 ppm (part per million) is difficult, but measuring ac phenomena, such as settling time, is even more difficult.Use a variable-transconductance amplifier instead of a diode bridge.Trim out delays and parasitic effects when possible.Be sure to verify your measurements.
Sidebars:
Components for 18-bit digital-to-analog conversion
DAC-amplifier compensation
Settling-time measurment of serial DACs
Delay and circuit-trimming procedures
Settling-time-circuit performance verification
Auxiliary circuits

Instrumentation, function generators, inertial navigation systems, ATE (automatic test equipment), medical apparatus, and other precision applications now require 18-bit converters. The resolutions of these converters are so precise that measuring various performance parameters is difficult. DACs’ dc specifications are relatively easy to verify, but their ac specifications require more sophisticated approaches to produce reliable information. A DAC’s settling time is the elapsed time from an input code application until the output remains within a specified error band around the final value. The settling time of a DAC and its output amplifier is difficult to determine at 18-bit, or 4-ppm, resolution. To measure an 18-bit DAC, you must use measurement techniques with 20-bit, or 1-ppm, resolution for settling times as short as 265 nsec. Manufacturers usually specify DACs’ settling times for a full-scale 10V transition.

Measuring anything at any speed to 20-bit, or 1-ppm, resolution is difficult (see sidebar “Components for 18-bit digital-to-analog conversion”). Dynamic measurement to 20-bit resolution is particularly challenging. Reliable 1-ppm DAC-settling-time measurement constitutes a difficult problem requiring exceptional care in approach and experimental technique. You can use an oscilloscope to accurately display DAC-settling-time information for a 10V step with 1-ppm, or 10- µV, resolution within 265 nsec. The approach permits observation of small amplitude information at the excursion limits of large waveforms without overdriving the oscilloscope.

DAC settling time has three distinct components: delay time, slew time, and ring time (Figure 1). The delay time is small and is almost entirely due to propagation delay through the DAC and the output amplifier. During this interval, no output movement occurs. During slew time, the output amplifier moves at its highest possible speed toward the final value. Ring time defines the region in which the amplifier recovers from slewing and ceases movement within some defined error band. A trade-off between slew and ring time normally exists. Fast-slewing amplifiers generally have extended ring times, complicating your amplifier choice and frequency compensation. Additionally, the architecture of fast amplifiers usually dictates trade-offs that degrade dc error terms (see sidebar “DAC-amplifier compensation”).

DAC settling time

Engineers have previously measured DAC settling time with the false-sum-node technique (Figure 2). The resistors and DAC form a bridge-type network. With ideal components, the DAC output steps to the negative reference voltage when the DAC inputs move to all ones. During slew, the diodes, which limit the voltage excursion, bind the settling node. When settling occurs, the oscilloscope probe’s voltage should be 0V. The resistor divider’s attenuation means that the probe’s output will be one-half of the DAC’s settled voltage.

In theory, this circuit allows you to observe settling to small amplitudes. In practice, you cannot rely on the circuit to produce useful measurements. The oscilloscope connection presents problems. As probe capacitance rises, ac loading of the resistor junction influences the settling waveforms. A 10-pF probe alleviates this problem, but its 10× attenuation sacrifices gain. Probes with 1× attenuation are not suitable because of their excessive input capacitance. An active 1× FET (field-effect-transistor) probe works but still presents a more significant issue: oscilloscope overdrive.

The clamp diodes at the settling node reduce swing during the amplifier’s slewing, which prevents the circuit from overdriving the oscilloscope. Unfortunately, oscilloscope-overdrive-recovery characteristics vary widely, and manufacturers do not usually specify them. The 400-mV drop across the Schottky diodes means that the oscilloscope may see an unacceptable overload.

An oscilloscope typically undergoes a 2× overdrive when you set it to 50 mV/division while measuring to a 10-bit resolution. A 10-bit resolution—10 mV at the DAC output—results in 5 mV at the oscilloscope. The desired 5-mV baseline is just discernible. At 12-bit or higher resolution, the measurement becomes hopeless. If you increase the oscilloscope’s gain, you also increase overdrive-induced errors. At 18 bits of resolution, there is no chance of measurement integrity.

Measuring 18-bit settling time requires a high-gain oscilloscope that is also immune to overdrive. You can address the gain issue by using an external wideband preamplifier that accurately amplifies the diode-clamped settling node. Only classic sampling oscilloscopes, which vendors no longer manufacture, offer inherent overdrive immunity. However, you can construct a circuit that uses sampling techniques to avoid the overload problem. You can also endow the circuit with features for measuring 20-bit DAC settling time.

To measure 20-bit DAC settling time, you connect the settling point to the preamplified oscilloscope with a switch (Figure 3). You control the switch state with a delayed pulse generator, which you trigger with the same pulse that controls the DAC. You arrange the delayed pulse generator’s timing so that the switch does not close until settling is nearly complete. In this way, you sample the incoming waveform in both time and amplitude. The oscilloscope never experiences overdrive, and no off-screen activity occurs.

The sampling switch has stringent requirements. It must faithfully pass signal-path information without introducing alien components, including those from the switch-command channel. Conventional choices for the sampling switch are JFETs (junction FETs), MOSFETs (metal-oxide-semiconductor FETs), and diode bridges (Figure 4).

The parasitic gate-to-channel capacitances of FETs result in a large feedthrough into the signal path from the gate drive. This feedthrough is many times larger than the signal you are observing, and it obviates the switch’s purpose. The small parasitic capacitance and the symmetrical differential structure of a diode bridge tend to cancel the drive signal and result in low feedthrough. You must perform dc and ac trims and use complex drive and support circuitry with a diode bridge. You can reliably measure DAC settling time to 16-bit resolution. Beyond 16 bits, residual feedthrough becomes objectionable, and you must use another approach.

You can construct a low-feedthrough, high-resolution switch using wideband active components. With this approach, you can maintain the switch’s control channel inband because its transition rate is within the circuit’s bandpass frequency. The circuit’s wide bandwidth means that you can always control the switch’s transition. You greatly reduce feedthrough by having no out-of-band response.

Some candidates for low-feedthrough electronic switches are theoretically possible but cumbersome to implement (Figure 5a and Figure 5b). You must optimize others for low feedthrough on the rising and falling control-pulse edges because of the multiplier’s unrestricted wideband response (Figure 5c). You can minimize falling-edge feedthrough by using the collapse of an amplifier’s transconductance when the control pulse goes low (Figure 5d). This approach allows you to minimize the feedthrough of the control pulse’s rising edge without regard to falling-edge effects. This feature provides a significant advantage for an electronic switch.

An electronic-circuit sampling switch uses a transconductance amplifier (Figure 6). The switch dynamics are exceptionally pure because the wideband control and signal paths faithfully track a 1000-to-1 transconductance change. You can carefully optimize the switched current source for the lowest feedthrough on the rising control edge without regard to the falling-edge characteristics. The transconductance collapses on the falling edge, which ensures low feedthrough for that condition. This technique prevents oscilloscope overdrive.

The detailed design switches signals over a ±30-mV range with peak control-channel feedthrough of only millivolts and settling times of less than 40 nsec (Figure 7). The unity-gain circuit approximates switch action by varying A1A’s transconductance. The amplifier and its transconductance-control channel are wideband components, permitting them to faithfully track rapid variations in a transconductance setting. This characteristic means that the amplifier is always in control, affording clean response and rapid settling to the input’s value.

Amplifier A1A is the wideband transconductance amplifier. You set its voltage gain by the current magnitude into its ISET (current-set) terminal and its output-resistor load. Amplifier A1B unloads A1A’s output. This amplifier provides a gain of two. When driving a back-terminated 50Ω cable, however, its effective gain is unity at the cable’s receiving end. The back termination establishes a 50Ω signal-path environment. The switch-control input controls current source Q1, which sets A1A’s transconductance and gain.

Q1 is gated off when you set the switch-control input at zero. The 10-MΩ resistor supplies 1.5 µA into A1A’s ISET pin, which results in a voltage gain of nearly zero. This action blocks the input signal. When you set the switch-control input high, Q1 turns on, sourcing 1.5 mA into the ISET pin, in turn forcing maximum transconductance and causing the amplifier to assume unity gain and pass the input signal. You use trims for zero and gain to ensure accurate input-signal replication at the circuit’s output. You purify turn-on switching with a 50-pF variable capacitor and use a 10-kΩ thermistor with a 3300-ppm/°C temperature coefficient at Q1. This approach compensates A1A’s transconductance temperature dependence to minimize gain drift.

When you set the aberration capacitance to 35 pF, the circuit cleanly switches a 10-mV input signal (Figure 8). When the control input (Trace A) is low, no output (Trace B) occurs. When the control input goes high, the output reproduces the input with feedthrough settling in 20 nsec. You don’t see turn-off feedthrough due to the transconductance reduction of 1000-to-1 and the attendant 25-fold decrease in the frequency bandwidth. You set the sweep speed to 10 nsec/division to examine the 0V-settling details (Figure 9). The output (Trace B) settles to within 1 mV within 40 nsec after the switch control (Trace A) goes high. The aberration capacitance damps the peak feedthrough excursion of 5 mV. If you set this capacitance to 0 pF, feedthrough increases to 20 mV (Figure 10). Settling time to within 1 mV remains at 40 nsec. Setting this capacitance to 35 pF minimizes the feedthrough amplitude but yields seven-times-higher rise time than is possible with a setting of 0 pF (Figure 11).

The small dc and ac error of a transconductance switch accommodates the application’s requirements. The low feedthrough becomes irrelevant because the DAC’s ring-time interval buries the small time and amplitude error, pointing the way toward practical 1-ppm DAC-settling-time measurements.

Measurement method

You can combine this electronic switch with the DAC-amplifier summing method (Figure 12). You split the delayed pulse generator into independently variable delay and pulse-generator blocks. You run the input step to the oscilloscope through a section that compensates for settling-time-path propagation delays. This path includes the settling node, the amplifier, and sample-gate delays. You drive the transconductance sampling switch from a nonsaturating residue amplifier, feeding the oscilloscope. Placing the sampling switch after the residue amplifier further minimizes sample-command feedthrough.

The 20-bit DAC-settling-time-measurement circuitry uses the input pulse to simultaneously switch all the DAC bits (Figure 13). You must use a modified circuit and a Microchip PIC microcontroller for serial DACs (see sidebar “Settling-time measurement of serial DACs”). You also route this pulse to the oscilloscope through the delay-compensation network, which comprises CMOS inverters and an adjustable RC network. It compensates the oscilloscope’s input step signal for the 44-nsec delay through the circuit-measurement path (see sidebar “Delay and circuit-trimming procedures”). You compare the DAC-amplifier output with the 10V reference using precision 10-kΩ summing resistors. The reference IC also furnishes the DAC reference, which makes the measurement ratiometric. A1, which also has voltage gain, unloads the clamped settling node. Amplifier A2 has a clamped output and provides a total amplification of 40 referred to the summing node. A2’s output feeds the sampling-switch circuit. The potentiometer adjusts the circuit’s gain.

You arrange the clamping and gain of A1 and A2 so that saturation never occurs. The amplifier is always in its active region. The input pulse triggers the 74HC123 dual one-shot. You control the pulse delay of the one-shot with a 20-kΩ potentiometer. If you set the delay appropriately, the oscilloscope sees no input signal until settling is nearly complete, thereby eliminating overdrive. You adjust the sampling switch’s on-time so that you can observe all remaining settling activity.

When the sample gate goes high, switching is clean, and you can easily observe the last millivolt of ringing time (Figure 14). The amplifier settles nicely to a final value. When the sample gate goes low, the transconductance switch goes off, and you can discern no feedthrough. There is never any off-screen activity, and the oscilloscope is never in overdrive.

To achieve this level of performance, you must trim the circuit (see sidebar “Delay and circuit-trimming procedures”). If you do a poor sample-interval-zero adjustment, the circuit shifts the output baseline (Figure 15). A proper adjustment yields a continual baseline (Figure 16). You can see the barely visible sample-command feedthrough at Trace B’s leading edge. Signal peaking goes to 350 µV, and settling is 50 nsec before your trimming aberrations and transition purity (Figure 17). By trimming these functions, you increase delay to 70 nsec from 20 nsec, but the signal peaks at only 50 µV (Figure 18). Signal settling remains at 50 nsec. At the sample-command turn-off, the 1000-to-1 transconductance drop ensures a clean transition independent of the turn-on optimizing trims (Figure 19).

Read more In-Depth Technical Features

You can graph the minimum measurable settling time for a given resolution (Figure 20). Sample-command-path delays and sample-gate switching-residue profiles impose speed limitations on the circuit. You can measure settling time below 160 nsec at 16-bit resolution. For smaller signals, the sample gate’s switching-residue profile dictates an increased minimum measurable settling time of 265 nsec at 20 bits. The DAC/amplifier, summing resistors, and residue amplifier/sampling switch impose circuit-noise limitations. Resolution beyond 15 ppm requires you to use filtering or noise-averaging techniques. You can drive the 74HC123’s B2 input with a phase-advanced version of the pulse-generator input to largely eliminate sample-command-path-delay-induced error. This approach considerably improves minimum measurable settling time. You must use careful construction techniques and proven diligent measurements (see sidebar “Settling-time-circuit performance verification”).

Circuit application

It is good practice to “walk” the sampling window backward in time from the settled region to the last 100 µV or so of amplifier movement so that you can observe the cessation of ringing. The sampling-based approach provides this capability and is a powerful measurement tool. Slower amplifiers may require extended delay, sampling-window times, or both, necessitating larger capacitor values in 74HC123 one-shot timing networks. Noise is the fundamental measurement limit with an unfiltered bandpass (Figure 21). The DAC (Trace B) settles to 16 bits, 1.7 µsec after Trace A’s time-corrected input step. The DAC amplifier’s compensation capacitor affects settling time (see sidebar “DAC-amplifier compensation”). Sample-gate feedthrough is undetectable, indicating that higher resolution is possible without overdriving the oscilloscope. Reducing the measurement bandwidth to 250 kHz attenuates noise (Figure 22). The 18-bit, or 4-ppm, settling requires approximately 5 µsec. The reduced bandwidth permits higher resolution, although the indicated settling time is likely pessimistic due to the filter’s lag. Decreasing bandwidth to 50 kHz permits 19-bit, or 2-ppm, resolution with an indicated settling in 9 µsec (Figure 23). The same filter that permits high resolution also creates a longer settling time.

You can use noise-averaging techniques to measure settling time to 20 bits, or 1 ppm (10 µV), without the time penalty of a bandlimiting filter (Figure 24). You can adjust the DAC amplifier for overdamped, underdamped, and optimum responses. Using averaging eliminates noise, permitting you to determine settling time due to DAC dynamics. In this case, settling time ranges from 4 to 6 µsec, and fractional LSB (least-significant-bit) tailing is evident. This measurement determines DAC settling time due solely to dynamics that a step input initiates. For this reason, you can consider averaged results academic. Noise limits the measurement certainty at any given instant to 100 µV. It is reasonable to maintain that this noise means that the DAC never settles inside this limit. The averaged measurement defines settling time after you remove noise limitations.



Components for 18-bit digital-to-analog conversion

Components suitable for 18-bit digital-to-analog conversion are members of an elite class (Table A). Eighteen binary bits is one part in 262,144—just 0.0004%, or 4 parts per million. This mandates a vanishingly small error budget, and the demands on components are high. The LTC2757 digital-to-analog converter listed in Table A uses Si-Chrome thin-film resistors for high stability and linearity over temperature. Gain drift is typically 0.25 ppm/°C, or about 4.6 LSBs (least significant bits) over 0 to 70°C. Some amplifiers shown contribute less than 1-LSB error over 0 to 70°C, with 18-bit DAC-driven settling times of 1.8 µsec available. The references offer drifts as low as 1 LSB over 0 to 70°C, with initial trimmed accuracy to 0.05%.


DAC-amplifier compensation

A number of practical considerations arise when you need to compensate a DAC-amplifier pair for the fastest settling time. Settling-time components include delay, slew, and ring times (Figure A). Delay, a small term, is due to propagation time through the DAC amplifier. The amplifier’s maximum speed sets the slew. Ring time defines the region in which the amplifier recovers from slewing and ceases movement within some defined error band. Once you choose a DAC-amplifier pair, you can readily adjust only the ring time. Because slew time is usually the dominant lag time, it is tempting to select the fastest-slewing amplifier available. Unfortunately, fast-slewing amplifiers usually have extended ring times, negating their brute-force speed advantage. The penalty for raw speed is, invariably, prolonged ringing, which you can damp only with large compensation capacitors. Such compensation works but results in protracted settling times.

The key to good settling times is to choose and properly compensate an amplifier with the right balance of slew rate and recovery characteristics. This task is harder than it sounds because you cannot predict or extrapolate amplifier settling time from any combination of data-sheet specifications. You must measure it in the intended configuration. A number of terms, including amplifier slew rate and ac dynamics, DAC output resistance and capacitance, and the compensation capacitor, combine to influence settling time. These terms interact in a complex manner, making predictions hazardous.

If you replace the DAC’s parasitics with a purely resistive source, you still cannot easily predict the amplifier’s settling time. The DAC’s output impedance further complicates a difficult problem. The only available approach for dealing with all these issues is to use a feedback-compensation capacitor. Its purpose is to roll off amplifier gain at the frequency that permits the best dynamic response. Normally, the DAC’s current output unloads directly into the amplifier’s summing junction, placing the DAC’s parasitic capacitance to ground at the amplifier’s input. The capacitance introduces a feedback phase shift at high frequencies. This shift forces the amplifier to “hunt” and ring about the final value before settling.

DACs have different values of output capacitance. CMOS DACs have the highest output capacitance—typically, 100 pF—and it varies with the digital input code. The best settling results when you select the compensation capacitor to functionally compensate for all the parasitics (Figure B). Trace A is the DAC input pulse, and Trace B is the amplifier’s settle signal. The amplifier comes cleanly out of slew and settles quickly.

If the feedback capacitor is too large—27 pF, for example—settling is smooth, although overdamped (Figure C). A 300-nsec penalty results. If the feedback capacitor is too small—15 pF, for example—it causes an underdamped response with excessive ring time (Figure D). The settling time increases to 2.8 µsec. Note that these compensation values for 18-bit settling do not necessarily indicate results for 16 or 20 bits. You must establish optimal compensation values for any desired resolution. Typical values range from 15 to 39 pF.

DAC, amplifier, and compensation-capacitor tolerances become irrelevant when you individually trim feedback capacitors for optimal response. If you don’t use individual trimming, you must consider these tolerances to determine the feedback capacitor’s production value. DAC capacitance, DAC resistance, and the value of the feedback capacitor affect the ring time. The relationship is nonlinear, although some guidelines exist.

The DAC’s impedance terms can vary by ±50%, and the feedback capacitor is typically a ±5% component. Additionally, amplifier slew rate has a significant tolerance, which the data sheet lists. To obtain a production-feedback-capacitor value, determine the optimum value by individual trimming with the production-board layout. The board layout’s parasitic capacitance also counts. Then, factor in the worst-case percentage values for the DAC’s impedance terms, slew rate, and feedback-capacitor tolerance. Combine this information with the trimmed capacitor’s measured value to obtain the production value. This budgeting is perhaps unduly pessimistic but will keep you out of trouble. A defensible compromise may be rms (root-mean-square) error summing.


Settling-time measurement of serial DACs

Measuring the settling time of serially loaded DACs requires additional circuitry. This circuitry must provide a start pulse to the settling-time-measurement circuit after serially loading a full-scale step into the DAC. Mark Thoren, applications-engineering manager for mixed-signal products at Linear Technology, designed and constructed a processor-based circuit that performs this task (Figure A). The start pulse (Trace A in Figure B) initiates the measurement. Traces B, C, and D are (chip select)/LD (load), SCK (serial clock), and SDI (serial data in), respectively. You measure Trace E, the resultant DAC output, for settling time in the usual way. Listing 1 provides the complete processor-software code.


Delay and circuit-trimming procedures

The settling-time circuit uses an adjustable delay network to correct the input pulse for delays in the signal-processing path. Typically, these delays introduce errors of a few percentage points, so a first-order correction is adequate. Setting the delay trim involves observing the network’s input-to-output delay and adjusting for the appropriate time interval. Determining the appropriate time interval is somewhat more complex. Measuring the settling-time circuit’s signal-path delay involves modifications (Figure A). These changes lock the circuit into its sample mode, permitting an input-to-output-delay measurement under signal-level conditions similar to normal operation. In Figure B, Trace A is the pulse-generator input at 200 µV/division. Note that a 10-kΩ/1Ω resistor divider feeds the settle node. Trace B shows the circuit output at A4, delayed by about 44 nsec. This delay is a small error, but you can readily correct it by adjusting the delay network for the same time lag. If you use a serial-DAC interface, you should add 10 nsec to the delay correction. Similarly, if you use a postamplifier, you must increase the delay correction by 17 nsec.

Use the following procedure to trim the settling-time circuit for optimum performance. You should make sure to perform these steps in order.
  1. Turn off the input pulses.

  2. Trim the “baseline zero” for 0V output at the oscilloscope at 10 mV/division or less.

  3. Disconnect the precision 10-kΩ resistors and the ground-settle node through the 5.1-kΩ unit.

  4. Set the sample delay to midrange and the sample-window width to minimum.

  5. Drive the pulse-generator input with a 40-kHz square wave.

  6. Adjust the “sample interval zero” for no offset between the sample interval and the unsampled baseline.

  7. Adjust the “sample-transition-purity” and “aberration” trims for minimum amplitude disturbances when the sample gate opens with oscilloscope horizontal at 50 nsec/division and the vertical sensitivity of 10 mV/division.

  8. Reconnect the precision 10-kΩ resistors and remove the 5.1-kΩ unit from the settle node.

  9. Adjust the delay compensation for a 44-nsec delay from the pulse generator input to the time-corrected output pulse.

  10. Turn off the input pulses. Disconnect the pulse generator and its 50Ω termination. Apply 5V dc to the pulse input.

  11. Connect Figure C’s network to the settle node. The added components shown furnish a 250-µV-dc gain-calibration source when you replace the input pulses with a 5V level. Under the figure’s conditions, the DAC assumes a 10V output with the 5.1-kΩ resistor mimicking the 10-kΩ divider’s output impedance at A1. You adjust the gain trim for a 10-mV-dc deflection at the oscilloscope. This step completes the trimming procedure, and the circuit is ready for use.


Settling-time-circuit peformance verification

Prudent investigation requires a performance verification of the testing method. Performance verification for the settling-time test circuit requires a high-purity pulse generator that quickly transitions and settles to 1 ppm (part per million). This requirement is a difficult one, and I am unaware of any electronic means of achieving this capability.

Fortunately, electromechanical technology offers a viable technique. You can use a mercury-wetted reed-relay pulse generator (Figure A). Theoretically, when the contacts open, an infinitely fast falling edge appears across the 50Ω termination with zero settling time to 0V. In reality, this action does not take place (Figure B).

A typical commercial relay shows a less-than-5-nsec transition with a 500-MHz ring-off of greater than 10 nsec. These imperfections are not surprising when you consider the parasitic terms (Figure C). Figure A’s deceptively simple schematic has a number of unintentional terms, including parasitic resistance, inductance, and capacitance and undesirable field interaction within the relay, which severely limit performance. Additionally, the connection through the relay to the output terminal constitutes an ill-defined transmission line, which promotes additional vagaries. The parasitic terms interact in a haphazard and unpredictable way, resulting in alien terms at the pulse output. The solution is to use a relay designed for inclusion in a wideband 50Ω system.

In the 1960s, Tektronix manufactured the Type 109 mercury-wetted reed relay for use as a pulse generator. In its preferred configuration, the relay switches energized charge lines into a 50Ω termination, resulting in a 250-psec rise-time pulse. This approach does not employ charge lines; rather, the device acts as a simple switch. The approach takes advantage of Tektronix’s exquisite care in manufacturing to make the relay transparent in a 50Ω system. A large-scale transition reveals an 800-psec fall time with a 1-GHz idth (Figure D). The actual fall time is probably somewhat shorter because the monitoring oscilloscope has a 350-psec rise time. The transition is singularly clean and devoid of discontinuities, with the exception of prefall corner rounding. Figure E shows sampling-switch techniques similar to the text’s to measure Type 109 relay fall-time purity to microvolts. The 109 relay’s output (Trace B) moves the final 220 µV, settling inside 10 µV approximately 265 nsec after the relay’s contacts open (Trace A). Actual 109 relay settling time may be shorter because the sampling circuit likely limits the measurement. Figure F shows a simplified version of the test circuit that produced these results. The Type 109 relay drives 20 cm of 50Ω GR-874 airline into a high-quality GR-874 50Ω termination at the clamped amplifier-sampling switch. The Tektronix pick-off components allow signal extraction from the airline without degrading transmission-line integrity. Note that using airline is a nonnegotiable requirement. The highest-quality Teflon 50Ω cable produces impure response, albeit minor.

It may be unrealistic for readers to duplicate the Tektronix 109-based results. The specified exotic apparatus is difficult and expensive to obtain, and the setup requires arduous labor and almost fanatical attention to detail. In this spirit, Figure G shows a “pretty good” mercury-wetted reed-relay pulse generator. Its performance, although falling well short of the circuit in Figure F, still furnishes a 10V step, which settles to 1 ppm in 950 nsec. A simple clock (“resonance set”) furnishes low-frequency drive to the relay through the transistor-level shift and the LT1010 power buffer. The paralleled CMOS inverters provide trigger pick-off. You must use separate packages for the resonance-set and trigger functions to avoid output-pulse contamination. Figure H shows results for the pretty good step generator. Its slower settling and alien residue components compared with the Tektronix 109 approach are apparent. The event at the 10th vertical division is sample feedthrough-related gate turn-off.

Circuit calibration involves adjusting the resonance set until the relay emits a reasonably pure audible tone. Next, setting the 20V supply to a value that promotes the cleanest settling characteristics.


Auxiliary circuits

Several auxiliary circuits are useful for DAC settling-time measurement. For example, you can use a simple, wideband, 10× preamplifier for oscilloscopes lacking the required sensitivity for 1-ppm, 10-µV settling-time resolution (Figure A). You should place this preamplifier directly at the oscilloscope’s input and connect it using 50Ω terminated BNC cable to the settling-time fixture output.

An autozero circuit locks the sample interval’s zero value to the nonsampled region’s baseline (Figure B). It eliminates the need for periodic readjustment of the sample-interval-zero trim when working at the highest levels of resolution over a protracted time. Synchronously switched A1 compares the sample interval’s and nonsampled region’s zero values and applies an appropriate offset, closing a correction loop around the LT1228. M1’s extended pulse precludes settling activity from influencing the sample interval’s zero value. The autozero-bias trim corrects for slight errors and should not require readjustment once you set it to equalize the sample interval’s zero value and the nonsampled region’s baseline. Figure C provides information for the autozero’s interconnection to the settling-time circuit. Signals include the time-corrected input pulse (Trace A), DAC output (Trace B), sample delay (Trace C), M1’s input (Trace D), M1’s sample-interval zero pulse (Trace E), G1’s sample command (Trace F), and settle signal’s output (Trace G). M1’s delayed output maintains the sample interval’s zero value independently of the settling signature.

You use a simple time calibrator to verify the oscilloscope’s timebase accuracy (Figure D). Q1 and Q2 form a 1-MHz quartz oscillator. The 74C90 provides switch-selectable output periods of 2 and 5 µsec, and the attenuator supplies 50Ω output impedance. The oscillator period is suitable for calibration points appropriate for expected DAC settling times. Other periods are available by varying the oscillator’s frequency, division ratio, or both. The 9V battery’s drain is approximately 10 mA.



References
  1. Williams, Jim, "Component and Measurement Advances Ensure 16-Bit DAC Settling Time," Application Note 74, Linear Technology Corp, July 1998.

  2. Williams, Jim, "Measuring 16-bit settling times: the art of timely accuracy," EDN, Nov 19, 1998.

  3. Williams, Jim, "Methods for Measuring Op Amp Settling Time," Application Note 10, Linear Technology Corp, July 1985.

  4. Demerow, Robert I, "Settling Time of Operational Amplifiers," Analog Dialogue, June 1970, pg 1.

  5. Pease, Bob, and Ed Maddox, "The Subtleties of Settling Time," The New Lightning Empiricist, Teledyne Philbrick, June 1971.

  6. Harvey, Barry, "Take the guesswork out of settling-time measurements," EDN, Sept 19, 1985.

  7. Williams, Jim, "Settling-time measurement demands precise test circuitry," EDN, Nov 15, 1984.

  8. Schoenwetter, Howard K, "High-Accuracy Settling Time Measurements," IEEE Transactions on Instrumentation and Measurement, Volume IM-32, No. 1, March 1983.

  9. Sheingold, DH, "DAC Settling Time Measurement," Analog-Digital Conversion Handbook, Prentice-Hall, 1986, pg 312.

  10. Williams, Jim, "30 Nanosecond Settling Time Measurement for a Precision Wideband Amplifier," Application Note 79, Linear Technology Corp, September 1999.

  11. Williams, Jim, "Evaluating Oscilloscope Overload Performance," Section A, "Methods for Measuring Op Amp Settling Time," Application Note 10, Linear Technology Corp, July 1985.

  12. Orwiler, Bob, Oscilloscope Vertical Amplifiers, Tektronix Inc, Concept Series, 1969.

  13. Addis, John, "Fast Vertical Amplifiers and Good Engineering," Analog Circuit Design: Art, Science and Personalities, Butterworth-Heinemann, 1991.

  14. Travis, W, "Settling Time Measurement Using Delayed Switch," Private Communication, 1984.

  15. Hewlett-Packard, "Schottky Diodes for High-Volume, Low Cost Applications," Application Note 942, Hewlett-Packard Co, 1973.

  16. Korn, Granino A, and Korn, Theresa M, Electronic Analog and Hybrid Computers, "Diode Switches," pg 223, McGraw-Hill, 1964.

  17. Carlson, R, "A Versatile New DC-500 MHz Oscilloscope with High Sensitivity and Dual Channel Display," Hewlett-Packard Journal, January 1960.

  18. "Sampling Notes," Tektronix Inc, 1964.

  19. Type 1S1 Sampling Plug-In Operating and Service Manual, Tektronix Inc, 1965.

  20. Mulvey, John, Sampling Oscilloscope Circuits, Tektronix Inc, Concept Series, 1970.

  21. Addis, John, "Sampling Oscilloscopes," Private Communication, February 1991.

  22. Williams, Jim, "Bridge Circuits-Marrying Gain and Balance," Application Note 43, Linear Technology Corp, June 1990.

  23. Type 661 Sampling Oscilloscope Operating and Service Manual, Tektronix Inc, 1963.

  24. Type 4S1 Sampling Plug-In Operating and Service Manual, Tektronix Inc, 1963.

  25. Type 5T3 Timing Unit Operating and Service Manual, Tektronix Inc, 1965.

  26. Morrison, Ralph, Grounding and Shielding Techniques in Instrumentation, Second Edition, Wiley Interscience, 1977.

  27. Ott, Henry W, Noise Reduction Techniques in Electronic Systems, Wiley Interscience, 1976.

  28. Williams, Jim, "High Speed Amplifier Techniques: A Designer’s Companion for Wideband Circuitry," Application Note 47, Linear Technology Corp, 1991.

  29. Type 109 Pulse Generator Operating and Service Manual, Tektronix Inc, 1963.

  30. Williams, Jim, "Signal Sources, Conditioners and Power Circuitry," Application Note 98, "Wideband, Low Feedthrough, Low Level Switch," pg 13, Appendix A, "How Much Bandwidth is Enough?" pg 26, Linear Technology Corp, November 2004.

  31. Williams, Jim, "Applications Considerations and Circuits for a New Chopper-Stabilized Op Amp," Linear Technology Corp, Application Note 9, March 1985.

Author Information
Jim Williams is a staff scientist at Linear Technology Corp, where he specializes in analog circuit and instrumentation design. He has served in similar capacities at National Semiconductor, Arthur D Little, and the Instrumentation Laboratory at the Massachusetts Institute of Technology (Cambridge, MA). A former student at Wayne State University (Detroit), Williams enjoys sports cars, art, collecting antique scientific instruments, sculpture, and restoring old Tektronix oscilloscopes.
RSS
Reprints/License
Print
Email
Talkback
Canon Resource Center

Featured Company


Most Recent Resources

Advertisement
Related Content

No related content found.

  • 0 rated items found.
Advertisement

KNOWLEDGE CENTER

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
Engineering Careers
Jobs sponsored by
Advertisement
About EDN   |   Site Map   |   Contact Us   |   Subscription   |   RSS
© 2012 UBM Electronics. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy

Please visit these other UBM Canon sites

UBM Canon | Design News | Test & Measurement World | Packaging Digest | EDN | Qmed | Pharmalive | Appliance Magazine | Plastics Today | Powder Bulk Solids | Canon Trade Shows