Shunt regulator serves as inexpensive op amp in power supplies

Use low-cost power-regulator IC to replace more costly op amp in power supplies.

Michael O'Loughlin, Texas Instruments, Nashua, NH; Edited by Brad Thompson and Fran Granville -- EDN, September 15, 2005

Developed as a three-terminal shunt regulator, the popular and multiple-sourced TL431 IC offers designers many intriguing possibilities beyond its intended application. Internally, the TL431 comprises a precision voltage reference, an operational amplifier, and a shunt transistor (Figure 1a). In a typical voltage-regulator application, adding two external resistors, RA and RB, sets the shunt-regulated output voltage at the lower end of load resistor RS (Figure 1b).

In today's power-supply market, cost reduction drives most designs, as evidenced by Asian manufacturers that have resorted to shaving pennies off their power-supply products by using single-sided pc boards. This Design Idea shows how a three-terminal shunt regulator can replace a more expensive conventional operational amplifier in a power-converter design.

A switched-mode power supply uses a galvanically isolated feedback portion of a PWM circuit (Figure 2). In designs that omit a voltage amplifier, a shunt regulator can serve as an inexpensive op amp. Resistors RI and R set the power supply's dc output voltage, and optocoupler IC2 provides galvanic isolation. Resistor R1 provides bias for the optocoupler and the TL431, IC1. Resistor R3 and zener diode D1 establish a fixed bias voltage to ensure that bias resistor R1 does not form a feedback path. Resistors R1 and R2 control the gain across the optocoupler. In most designs, the ratio of R2 to R1 is roughly 10-to-1.


Components CP, CZ, and RZ provide frequency compensation for the control loop. The optocoupler includes a high-frequency pole, fP, in its frequency response, an item that most optocouplers' data sheets omit. You can use a network analyzer to determine the location of the high-frequency pole or estimate that the pole occurs at approximately 10 kHz. The following equation describes the compensation network's small-signal transfer function:


Note that, under some circumstances, adding a bypass capacitor across diode D1 may be necessary for output-noise reduction.

 

Click here for more Design Ideas!

RSS
Reprints/License
Print
Email
Talkback
Canon Resource Center

Featured Company


Most Recent Resources

Advertisement
Related Content

No related content found.

  • 0 rated items found.
Advertisement

KNOWLEDGE CENTER

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
Engineering Careers
Jobs sponsored by
Advertisement
About EDN   |   Site Map   |   Contact Us   |   Subscription   |   RSS
© 2012 UBM Electronics. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy

Please visit these other UBM Canon sites

UBM Canon | Design News | Test & Measurement World | Packaging Digest | EDN | Qmed | Pharmalive | Appliance Magazine | Plastics Today | Powder Bulk Solids | Canon Trade Shows