Low-cost circuit incorporates mixing and amplifying functions

Using an amplifier with a power-down disable, you can combine the mixer and the amplifier functions.

Guus Colman, Guy Torfs, Johan Bauwelinck, and Jan Vandewege, INTEC/IMEC, Ghent University, Ghent, Belgium; Edited by Martin Rowe and Fran Granville -- EDN, July 10, 2008

In many applications, the frequency-conversion steps comprise a buffer, preferably with some extra voltage gain; a mixer; and some filtering. Instead of including an amplifier in front of the mixer, you can easily integrate the mixer function with the amplifier. A low-cost implementation uses an amplifier with a power-down-disable feature. When a square-wave local oscillator drives the disable pin, a square wave at the oscillator’s frequency multiplies the input signal, and frequency conversion takes place.

The circuit in Figure 1 uses an Analog Devices low-cost, 300-MHz, rail-to-rail AD8063 amplifier. The test circuit comprises a noninverting-op-amp circuit, which drives a load of 4 kΩ. The two resistors in the feedback loop regulate the voltage-conversion gain. In the test circuit, the voltage gain is 20 dB. However, you must consider the switching loss, which is about 10 dB when using an ideal switch and a 50%-duty-cycle clock. This scenario results in a 10-dB voltage-conversion gain.

Because the switching interrupts the power-supply current, the device’s turn-on and turn-off times have a non-negligible influence on conversion gain and nonlinearities. The AD8063’s turn-on time, at 40 nsec, is less than the turn-off time of 300 nsec. In these cases, more signal power passes to the output, which results in an increase in voltage-conversion gain. Figure 2 shows the voltage-conversion gain of the test circuit when downconverting an input signal to 12 kHz with a local-oscillator duty cycle of 50%. You can easily adjust this conversion gain by changing the two resistors in the feedback loop.

Another aspect of a mixer’s ac performance is distortion. The test circuit maintains a second-order harmonic distortion of 35 dB and a third-order harmonic distortion of 43 dB when mixing a 5-MHz signal to a 12-kHz, 1V-p-p output signal. The circuit can downconvert two sine waves of identical power at 5 and 5.002 MHz to 12 and 14 kHz, respectively, with an intermodulation distortion of 47 dB.

RSS
Reprints/License
Print
Email
Talkback
Canon Resource Center

Featured Company


Most Recent Resources

Advertisement
Related Content

No related content found.

  • 0 rated items found.
Advertisement

KNOWLEDGE CENTER

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
Engineering Careers
Jobs sponsored by
Advertisement
About EDN   |   Site Map   |   Contact Us   |   Subscription   |   RSS
© 2012 UBM Electronics. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy

Please visit these other UBM Canon sites

UBM Canon | Design News | Test & Measurement World | Packaging Digest | EDN | Qmed | Pharmalive | Appliance Magazine | Plastics Today | Powder Bulk Solids | Canon Trade Shows