Achieve precision temperature control with TEC Seebeck-voltage sampling

By periodically setting the TEC's drive to zero, a storage capacitor samples and holds the Seebeck voltage.

W Stephen Woodward, Chapel Hill, NC; Edited by Martin Rowe and Fran Granville -- EDN, November 27, 2008

TEC (thermoelectric-cooler) temperature-control systems often have limited stability. The causes of these limitations are the thermal properties of the system, not the performance of the control electronics. Real-world thermal-control systems incur nonzero thermal impedances in the heat-transfer paths between the TEC; the thermal load, which is the object of thermostasis; the temperature sensor—for example, a thermistor; and the ambient temperature.

If the ratios of these impedances don’t balance, then even perfect thermostasis of the sensor’s temperature doesn’t equate to adequate stability of the load’s temperature. The circuit in Figure 1 provides a thermoelectronic design that directly measures the heat flux through the TEC and then uses the measurement to better estimate and cancel the effects of thermal impedances. Its operation is based on the fact that the total voltage that every TEC develops is the sum of two components: an ohmic component proportional to drive current and the Seebeck voltage, VS, which is proportional to the temperature difference across the TEC and, therefore, to heat flux.

See all of EDN's
Design Ideas

In this circuit, however, the drive current switches to zero approximately every 100 µsec because of the asymmetrical sample-pulse waveform that multivibrator S2/S3 generates. Each sample pulse turns off 5V transistor Q1, which isolates the Seebeck voltage and allows its sampling through S1 and storage capacitor C1 to hold it. The duty factor of the sampling pulse, which the R1-to-R2 ratio sets, is less than 10% to avoid significantly reducing the TEC-drive capability of the circuit.

You apply the acquired Seebeck signal to the R3/R4/R5 adjustable-bridge circuit, which empirically determines the feedback ratio for both polarity and amplitude to provide best stability. With proper bridge adjustment, you can make gradient cancellation nearly perfect over a wide range of ambient temperatures. The TEC-control circuit in Figure 1 derives from a previous Design Idea because it eases the incorporation of Seebeck sampling (Reference 1). You can, however, adapt Seebeck sampling to virtually any TEC-drive topology. You can further enhance the circuit in Figure 1 by using nonvolatile, in-circuit-programmable resistors for the R3/R4/R5 bridge, automatically optimizing gradient cancellation. One attractive choice is the Rejustor family of monolithic resistors from Microbridge Technologies.


Reference
  1. Woodward, W Stephen, “Thermoelectric-cooler unipolar drive achieves stable temperatures,” EDN, Dec 3, 2007, pg 98.

RSS
Reprints/License
Print
Email
Talkback
Canon Resource Center

Featured Company


Most Recent Resources

Advertisement
Related Content

No related content found.

  • 0 rated items found.
Advertisement

KNOWLEDGE CENTER

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
Engineering Careers
Jobs sponsored by
Advertisement
About EDN   |   Site Map   |   Contact Us   |   Subscription   |   RSS
© 2012 UBM Electronics. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy

Please visit these other UBM Canon sites

UBM Canon | Design News | Test & Measurement World | Packaging Digest | EDN | Qmed | Pharmalive | Appliance Magazine | Plastics Today | Powder Bulk Solids | Canon Trade Shows