Power meter is ±1% accurate

Edited by Bill Travis

By Ken Yang, Maxim Integrated Products, Sunnyvale, CA -- EDN, May 30, 2002

Power meters provide an early warning of thermal overload by monitoring power consumption in high-reliability systems. Power monitoring is especially suitable for motor controllers, industrial heating systems, and other systems in which the load voltage and current are both variable. The power meter/controller in Figure 1 uses the principle that power is the product of voltage and current. The typical accuracy of the circuit is better than ±1%. A current sensor, IC2, measures output current, and a four-quadrant analog-voltage multiplier, IC1 and IC3, generates the product of output voltage and current. An optional unity-gain inverter, IC4, inverts the inverted multiplier output. This power meter is most accurate for multiplier inputs (J1 and J2) of 3 to 15V. Select the current-sense resistor as follows: RSENSE=1/P, where RSENSE is in ohms, and P is the output power in watts. If power delivery to the load is 10W, for example, you would choose RSENSE=0.1Ω.

The circuit in Figure 1 has a unity-gain transfer function, in which the output voltage is proportional to load power. For instance, the output voltage is 10V when the load power is 10W. To change the transfer-function gain, change the sense resistor as follows: Gain=10RSENSE. For the circuit in Figure 1, Figure 2 compares power-measurement error with load power. Note that accuracy is better than ±1% for load power of 3 to 14W. For proper operation, you must first calibrate the analog multiplier according to the following procedure. Remover jumpers J1 (X input) and J2 (Y input) before calibration.

  • X-input offset adjustment: Connect a 1-kHz, 5V p-p sinusoidal signal to the Y input, and connect the X input to ground. Using an oscilloscope to monitor the output, adjust RX for an ac null (zero amplitude) in the sinusoidal signal.

  • Y-input offset adjustment: Connect a 1-kHz, 5V p-p sinusoidal signal to the X input, and connect the Y input to ground. Using an oscilloscope to monitor the output, adjust RY for an ac null (zero amplitude) in the sinusoidal signal.

  • Output-offset adjustment: Connect both X and Y inputs to ground. Adjust ROUT until the dc output voltage is 0V.

  • Scale factor (gain): Connect both X and Y inputs to 10V dc. Adjust RSCALE until the output voltage is 10V dc.

  • Repeat the preceding steps as necessary.

Is this the best Design Idea in this issue? Select at www.ednmag.com.

RSS
Reprints/License
Print
Email
Talkback
Canon Resource Center

Featured Company


Most Recent Resources

Advertisement
Related Content

No related content found.

  • 0 rated items found.
Advertisement

KNOWLEDGE CENTER

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
Engineering Careers
Jobs sponsored by
Advertisement
About EDN   |   Site Map   |   Contact Us   |   Subscription   |   RSS
© 2012 UBM Electronics. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy

Please visit these other UBM Canon sites

UBM Canon | Design News | Test & Measurement World | Packaging Digest | EDN | Qmed | Pharmalive | Appliance Magazine | Plastics Today | Powder Bulk Solids | Canon Trade Shows