Circuit lets you isolate and measure current
Isolation lets you measure current with an oscilloscope or other grounded probe.
Anton Mayer, Murr, Germany; Edited by Martin Rowe and Fran Granville -- EDN, September 23, 2010
| View as PDF |
You often need to measure current during circuit design and debugging. You can perform that task by breaking a path, inserting a shunt resistor, measuring its voltage, and converting the voltage to current. Unfortunately, that approach is sometimes impractical with an oscilloscope because one side of an oscilloscope probe connects to ground. Thus, you need to isolate the oscilloscope from the circuit under test.
The circuit in Figure 1 produces a
voltage proportional to current and isolates
the oscilloscope from the measurement
point. The circuit uses IC1, an
HCPL7800 isolation amplifier, which
adds input-to-output isolation of as much as 890V. It also amplifies its input voltage
by eight. Table 1 shows the overall
gain for each input range. The circuit’s
bandwidth is typically 100 kHz.

A set of switches lets you select a range of current to measure by inserting resistors into the circuit. Use resistors with 1% or less tolerance to minimize errors. For example, when you close S4, you select the 100-μA range. The unknown current passes through serial resistors R1 and R2, which have values of 1 and 0.25Ω, respectively. Thus, the voltage at IC1’s inputs is IIN×1.25 kΩ; if the input current is 100 μA, the voltage at IC1 is 125 mV. The circuit has a gain of eight, yielding 125 mV times 8, or 1V. The LM358 acts as a unity-gain differential amplifier. For best linearity, the input voltage at IC1 should not exceed ±200 mV.
| Read More Design Ideas |
When battery switch S5 closes and the voltage of the battery is sufficient for the circuit, LED1 illuminates for approximately 3 seconds. The duration of this illumination minimizes drain on the battery. LED2 is on when the 9 to 11V power supply is operating. IC5, an L272, provides an additional ground potential halfway between the supply voltage. With this split supply, you can measure both positive and negative currents.