Design Idea

Indicator features expanded scale

Edited by Bill Travis

By Abel Raynus, Armatron International, Melrose, MA -- EDN, 2/21/2002

Test equipment for a production line should be user-friendly (read "idiot-proof") and should offer minimal test time. In many cases, the test fixture must give an operator only one answer: pass or fail. Usually, two indicators assume this role: green for pass and red for fail. In most applications, a sensor transforms the tested parameter to a voltage; the test fixture must measure this voltage and display the result. Sometimes, an operator needs to observe the dynamics of the tested parameter to verify that the results are inside the permitted "green zone." For example, when evaluating a regulated system's behavior, the operator is often interested in measuring the parameter's deviation and estimating its average value after the process reaches steady state (Figure 1). In this situation, using an analog meter with marked red and green zones is preferable to using a digital or bar-graph LED display.

Assume that the range of the tested voltage is 4.75 to 5V. To make a voltmeter with maximum 5V reading by using a 100-µA dc meter, you would use a series resistor of 50 kΩ. The meter scale is linear, and the tested voltage zone represents only 5% of full-scale (Figure 2). It is difficult for an operator to observe the meter reading inside such a narrow zone. It would be desirable to expand the test zone to, say, 90% of full-scale (Figure 3). The circuit in Figure 4 does just that. When the tested voltage, VTEST, is lower than the threshold voltage, V2, the diode, D1 does not conduct, and the voltmeter comprises the microammeter and resistor, R1. When the tested voltage surpasses the threshold V2, the diode conducts, and resistor R2 connects in parallel with R1. The voltmeter's impedance decreases, thereby expanding the measurement scale. You can calculate the values of resistors R1, R2, and R3 as follows:

  • The voltage at the beginning of the tested zone, 4.75V, should consume 10% of the scale, with a corresponding current of 10 µA. Hence, neglecting the internal meter impedance, R1 equates to 4.75V/10 µA, or 475 kΩ.
  • After the measured voltage exceeds the threshold level, 4.75V, the voltmeter impedance equates to R1,2=(5–4.75)V/(100–10) µA, or 2.8 kΩ.
  • Hence, (R1R1,2)/(R1–R1,2)=(475×2.8)/(475–2.8)=2.8 kΩ, and R3=R2(VCC/V2–1)=2.8 (5/4.75–1)=147Ω.

Is this the best Design Idea in this issue? Select at www.ednmag.com.



Reed Business Information Resource Center

Featured Company


Most Recent Resources

ADVERTISEMENT

ADVERTISEMENT

Feedback Loop


Post a CommentPost a Comment

There are no comments posted for this article.

Related Content

 

By This Author


ADVERTISEMENT

Knowledge Center



Technology Quick Links

EDN Marketplace


©1997-2009 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy

Please visit these other Reed Business sites