Smack attack
Terry Staler, Specialty Concepts Inc - April 19, 2012
After graduating from college in 1976 with my brand-new
bachelor’s degree in electrical engineering, I
went to work for a small southern California company
that produced telephone-usage-monitoring
equipment. My responsibilities included those of a
junior engineer, technician, purchasing agent, and
assemblyman. (The company was really small.) Our first product
connected to phone lines in large corporate phone systems and
recorded the number of calls placed and total off-hook time. This
monitoring allowed the accounting department to compare phone
bills with actual usage and to catch any overcharges or abuse of
phone usage.Each unit was in a plastic box that measured about 8×12×3 in. and contained a handful of ICs; a PCB; a transformer; a 5V-dc supply; and a wheeled counter and timer, both 120V ac. A circular connector at the top of the unit mated with a phone-company-installed socket. We could view the counter and timer’s wheels through slots in an aluminum front panel. During testing, these units performed flawlessly, both in our lab and at a few smaller beta test sites. When we started to perform larger installations, however, we received some complaints. The counter would show two, three, or four calls when only one had actually occurred. We confirmed this information by comparing timer information with the number of calls; the average call was just too short.
I received the unenviable job of trying to solve the problem on-site. I drove to the company, which had more than 10,000 employees; checked in at the front desk; and was escorted to the phone-equipment room. This hot and humid room contained what looked like a million punch blocks and an infinite amount of wire covering every square inch. Our units—all clicking merrily away—were hanging from several hundred sockets. At random, I watched one unit, and, sure enough, I saw the counter advance two or three times in quick succession. I disconnected this unit and brought it back to our lab for troubleshooting. Yet, try as I might, I could never get it to fail, despite subjecting the unit to heat, humidity, and occasional sharp smacks with the palm of my hand. Talk about abuse!
Reinstalling the unit produced the expected result: random counts. Switching this unit with another may or may not solve the problem. In other words, this problem was random and intermittent—every engineer’s nightmare.
So the burning of the midnight oil began. Because we could not replicate the failure in our lab, we reinstalled the units at the customer’s site. At one point, we had 20 more bypass capacitors than ICs on the board. We redesigned the 5V power supply. Nothing worked.
As the junior engineer, I was assigned the task of sitting in the hot and humid equipment room with my X-acto knife and soldering iron, making repairs at the site. A week later, all of the units were working perfectly.
We never determined why the units failed at the site but not in our lab, but we suspected that the ac spike from the counter’s firing coupled into the IC was just below the threshold at which a false signal would occur. Something at the site had pushed the signal to the limit, perhaps because of the phenomenal number of wires, with their attendant radiated noise, covering the entire facility. Proper and careful PCB layout could have averted this problem.
Terry Staler is president of Specialty Concepts Inc (Chatsworth, CA). He treats newbie engineers with great respect.
BigDog robot: a sensor-based enhancement of human capabilities
The Black and Decker GH1000 Type 2 string trimmer
War of currents: Tesla vs Edison
Some thoughts on DC/DC converters, part one
Gnat-power sawtooth oscillator works on low supply voltages
Understanding the basics of setup and hold time
Why bypass caps make a difference - Part 1: How a regulator and its output capacitor can interact
Simple reverse-polarity-protection circuit has no voltage drop
Simulation shows how real op amps can drive capacitive loads
Datasheets.com Parts Search
185 million searchable parts
(please enter a part number or hit search to begin)
KNOWLEDGE CENTER